17505290637(微信同号)
全國咨詢服務熱線:
17505290637外觀 | A highly efficient, modular, 500 kVA scalable to 1000 kVA 3-phase UPS that provides the performance, flexibility, and maximized asset utilization today’s large data centers and mission critical applications require. This EcoStruxure Ready UPS features up to 99% efficiency with patented ECOnversion technology. Includes 5x8 start-up service. | |
---|---|---|
交期 | 特别訂單 -- 需要提供交付周期 |
附帶設備 | 安裝指南 | |
---|---|---|
Number of power module free slots | 0 | |
Number of power module filled slots | 0 | |
redundant | No | |
UPS size | WS |
顔色 | White | |
---|---|---|
深度 | 90 cm | |
高(gāo)度 | 197 cm | |
mounting preference | No preference | |
産品淨重 | 2030 kg | |
安裝類型 | Not rack-mountable | |
two post mountable | 0 | |
USB compatible | No | |
寬度 | 240 cm |
網絡頻率 | 40...70 Hz | |
---|---|---|
其他輸入電(diàn)壓 | 380 V | |
大(dà)輸入電(diàn)流 | 851 A | |
大(dà)耐受短(duǎn)路電(diàn)流 (Icw) | 100 kA | |
輸入總諧波失真 | 小(xiǎo)于3%的滿負荷 | |
輸入電(diàn)壓 | 3 相 | |
load power factor | 從0.7先到0.5滞後,無降容條件下 |
額定功率 [W] | 500000 W | |
---|---|---|
大(dà)可(kě)配置功率(瓦) | 1000000 W | |
輸出頻率 | 50 Hz sync to mains | |
其它輸出電(diàn)壓 | 380 V | |
波峰系數(shù) | 3 with THC <5% | |
拓樸 | 雙轉換聯機 | |
波形類型 | 正弦波 | |
輸出電(diàn)壓 THD | < 2% linear load and < 3% non-linear load | |
過載工作(zuò) | 125% 時(shí)為(wèi) 10 分鍾,150% 時(shí)為(wèi) 60 秒(miǎo) | |
curve equation | Efficiency | |
curve fixed loss | 0.0063 | |
curve load maximum | 100 % | |
curve load minimum | 1 % | |
curve proportional loss | 0.0042 | |
curve square loss | 0.038 | |
curve X-axis maximum | 100 % | |
curve test cond ID | 根據不間(jiān)斷電(diàn)源的“能量之星”測試方法測量的數(shù)據的曲線拟合。所有(yǒu)測量值均采用正常運行(xíng)模式在标準環境條件下測得(de),其中輸入為(wèi)400V/50Hz,輸出為(wèi)平衡電(diàn)阻性負載 (PF = 1.0)。 | |
curve X-axis minimum | 0 % | |
curve X-axis title | Load | |
curve X-axis units | Percentage | |
curve Y-axis maximum | 100 % | |
curve Y-axis minimum | 50 % | |
curve Y-axis title | Efficiency | |
curve Y-axis units | Percentage | |
graph display | 1 | |
output voltage | 400 V 3 phases | |
Maximum configurable power in VA | 1000000 VA | |
額定功率 [VA] | 500000 VA |
産品認證 | CUL listed | |
---|---|---|
符合标準 | IBC 2012 |
運行(xíng)溫度 | 0…40 °C | |
---|---|---|
相對濕度 | 0…95 % 非凝結 | |
工作(zuò)海拔 | 0...3333 ft | |
貯存環境溫度 | -15…40 °C | |
存儲高(gāo)度 | 0.00…15240.00 m | |
聲響級别 | 69.5 dBA | |
熱消散 | 80387 Btu/h | |
show note OP temperature | No | |
IP 保護等級 | IP20 |
電(diàn)池類型 | 外部電(diàn)池系統 | |
---|---|---|
預裝電(diàn)池 | 0 | |
空(kōng)電(diàn)池槽 | 0 | |
電(diàn)解液值 | 0 | |
電(diàn)源電(diàn)壓 | 480V | |
電(diàn)池電(diàn)壓放電(diàn)結束 | 384 V DC | |
battery curve | B | |
Battery power in VAH | 0 VAh runtime | |
可(kě)自動檢測、可(kě)擴展的延時(shí)時(shí)間(jiān) | 0 |
空(kōng)閑槽 | 2 | |
---|---|---|
控制(zhì)面闆 | 7" touch screen display | |
有(yǒu)聲報警 | Audible and visible alarms prioritized by severity |
包裝重量 | 2592 kg |
---|
保修單 | 廠家(jiā)授權的啓動裝置提供 1 年現場(chǎng)保修或保換 |
---|